| Model | AG-1120 |
| Packing Detail | 2440mm×1100mm×1420mm, N.W.: 350KG, G.W.: 480KG |
| Structure / C-arm | Electric Ascending A Descending of pillar movement: 400mm Forward and Backward Movement: 200mm Revolution around Horizontal Axis: ±180° Revolution around Vertical Axis: ±15° Slip on orbit: 120°(+90°~ -30°) Monitor Rotation: 300° SID: 960mm Opening: 760mm Arc depth: 640mm |
| Machine Size (Max) | Length: 240cm, Width: 81cm, Height: 221cm G.W.: 370KG |
| III. Configuration / Item | Quantity |
| Structure / Directive wheel | Direction wheel 360°rotation, main wheel ±90°rotation |
| Video System / CCD Video camera | Medical Mega-pixels digital CCD camera |
| Video System / Image Intensifier | TOSHIBA 9″ Image Intensifier 3-fireds |
| Video System / Digital workstation | Storage without damage, multi-images display, image W/L real-time adjustment, grayscale switch, region of interest balance, GAMMA correction, flip, noise reduction, intensifying, smoothing, sharpening, compression, zoom in, measurement, remark, picture-text typeset print, expert template, DICOM image transmit, DICOM image print, cine loop, image imprinting, Worklist registration etc. |
| Video System / 24’’ LCD monitor | 1920x1080, 60 Hz |
| III. Configuration / Hand controller | 1 |
| III. Configuration / Mainframe of C-arm | 1 |
| Electrical Performance / Film holder Size | 200mm×250mm(8″×10″) or 250mm×300mm(10″×12″) |
| III. Configuration / 24’’ LCD monitor | 1 |
| Electrical Performance / Manual Fluoroscopy | Tube Voltage:40kV~120kV continuous adjustment Tube Current:0.3mA~4mA continuous adjustment |
| Electrical Performance / Pulsed Fluoroscopy | Tube Voltage:40kV~120kV continuous adjustment Tube Current:0.3mA~30mA continuous adjustment |
| Electrical Performance / Automatic Fluoroscopy | Tube Voltage:40kV~120kV automatic adjustment Tube Current:0.3mA~4mA automatic adjustment |
| III. Configuration / Imported mini groove grid | 1 |
| III. Configuration / Red light cross localization | 1 |
| X-ray Tube / X-ray Tube Special for High Frequency | Fixed anode Dual-focus, small focus: 0.6, large focus:1.8mm Thermal capacity: 35.5KJ (47KHU) |
| III. Configuration / Electrically adjustable collimator | 1 |
| Electrical Performance / Photography Tube Voltage, mA, mAs | 40 kV~120 kV 25-100mA 1-180mAs |
| III. Configuration / Medical Mega-pixels digital CCD camera | 1 |
| Electrical Performance / High-Frequency Inverter Output Power | Output Power: 5kW Inverter Frequency:40kHz |
| III. Configuration / Toshiba 9’’ 3 fields image intensifier | 1 |
| III. Configuration / Digital workstation and Veterinary software | 1 |
| III. Configuration / X-ray generator and high frequency inverter power supply | 1 |