1 / 5
Digital Mammography X-ray System XF-INM-5kW
SKU: MW-XF-INM-5kW
!!The cost for 110 or 120V requires an additional transformer (including the transformer). This needs to be settled together with the optional equipment costs.!! Introduction INM-5kW Digital Mammography System is a professional equipment for breast diseases examination. It is suitable for early detection of mammary gland lesions. This system adopts the latest technology of flat panel detector, which has a higher sensitivity to X-ray. Its resolution reaches the value of 60lp/cm.
Price on request
Sign in and submit a request to see pricing for this product.
Specifications
| Model | XF-INM-5kW |
| Package Weight | 250kg |
| Country of Origin | china |
| Workstation / HDD | 500GB |
| Package Dimensions | 2030*875*1330mm |
| X-ray Tube / Brand | IAE (Italy) |
| Workstation / Memory | 4GB |
| Workstation / Monitor | 24’’ LCD |
| X-ray Generator / mAs | 0.5mAs-560mAs |
| Workstation / DICOM3.0 | Query for integration with any PACS |
| Mechanical Device / SID | 650mm |
| Workstation / Functions | Import/export function |
| X-ray Tube / Anode type | Rotating Anode |
| X-ray Generator / Current | 10-200mA |
| X-ray Generator / Voltage | 20-40KV |
| Workstation / Dual-core CPU | 3.3GHz |
| X-ray Generator / Frequency | 80-200KHZ |
| X-ray Tube / Maximum voltage | 40KV |
| X-ray Tube / Target material | Molybdenum |
| X-ray Tube / Focal spot value | 0.1mm /0.3mm |
| X-ray Generator / Output power | 5.0KW |
| Workstation / Discrete Graphics | 1920*1200 |
| X-ray Generator / Exposure time | 5-10000ms |
| Ambient Conditions / Atmospheric | 70~106kPa |
| X-ray Tube / Anode rotation speed | 10000rpm |
| Compression Paddle / Movement type | Electric |
| Mechanical Device / Exposure field | 240mm*300mm(Maximum) |
| Compression Paddle / Pressure range | 0~20kg (0.1kg step) |
| Ambient Conditions / Relative humidity | 30%~75% |
| Ambient Conditions / Ambient temperature | 10℃~40℃ |
| X-ray Generator / Self-diagnostic system | Tube overload protection |
| X-ray Tube / Anode heat storage capacity | 300KHU |
| X-ray Tube / House heat storage capacity | 426KHU |
| Compression Paddle / Up-down movement range | ≥210mm |
| Mechanical Device / Rotational angles of tube | -30°~+30° |
| Mechanical Device / Up-down movement of c-arm | ≥600mm |
| Mechanical Device / Rotational angles of c-arm | -90°~+90°(Electromagnetic lock) |
| Compression Paddle / Size of compression paddle | 260mm*180mm |
| X-ray Tube / Maximum anode heat dissipation rate | 500W |
| X-ray detector( Flat Panel Detector) / Active area | 235*290mm |
| X-ray detector( Flat Panel Detector) / Pixel pitch | 85um |
| X-ray detector( Flat Panel Detector) / Active pixel | 2762*3408 |
| X-ray detector( Flat Panel Detector) / Scintillator | Cesium Iodide |
| X-ray detector( Flat Panel Detector) / AD Conversion(bit) | 16 |
| X-ray detector( Flat Panel Detector) / Spatial resolution | 60Lp/cm |