Delivery location+675 72 111 999Consulting & AdvisoryFor Institutions & Bulk Orders
FTIR8800 Fourier transform infrared spectrometer SL-FTIR8800 — view 1
1 / 3

FTIR8800 Fourier transform infrared spectrometer SL-FTIR8800

SKU: MW-SL-FTIR8800
Price on request

Sign in and submit a request to see pricing for this product.

Specifications

ModelSL-FTIR8800
Interferometeroptical compensation type Michelson interferometer, optical path out optical hole with multilayer coating potassium bromide structure, optical path automatic correction, the whole machine anti-static integrated forming shell.
Wavenumber range4000-400cm-1(2.5-25μ m), can be extended to 7800-350cm-1, scanning speed: 2mm / S.
Country of Originchina
Software functionThis software can meet the requirements of all standard analysis, including spectral data processing, instrument control, and multiple map simultaneous preview. Filtering, baseline correction, interactive editing, and data manipulation are also provided on analytical models of interferograms or spectra. At the same time, there are spectral deduction, hybrid deduction, filter derivative, spectrum preview and other functions. The data input and output can be in ASCII or JCAMP format, with Txt / Excel data. Supporting the analytical atlas library.
Wavenumber accuracy0.01cm-1, baseline flatness: 0.1%T, better than the resolution of 1.0cm-1. KBR, aperture ratio 1 / 3.2.
Equipment Signal-to-noise ratio30,000:1 (RMS value, around 2100 cm-1,4 cm-1 resolution, 1 minute data acquisition).
Instrument characteristics / Easy debuggingthe energy of the interferometer can be adjusted without opening the cover.
Instrument characteristics / Good stabilityusing the new Michelson self-compensation optical system, can be dynamic correction, small size.
Instrument characteristics / Powerful softwaredata processing, instrument control, multi-map preview and other functions.
Instrument characteristics / Strong scalabilitylarge sample space, can meet all the operational needs of the FTIR spectral analysis samples, transmission test, attenuation total reflection test, mirror reflection test, etc.
Instrument characteristics / Convenient maintenancethe desiccator can be replaced without opening the main machine.
Instrument characteristics / Fast test speed, high accuracyultra-high sensitivity design, equipped with DLATGS greenhouse detector, real-time spectral data collection, with USB2.0 communication interface, improve the data transmission rate, test a sample only needs a few seconds.
Instrument characteristics / Strong adaptability to the environmentthe interferometer adopts multiple sealing moisture-proof, dustproof design, visible silicone window is easy to observe and replace.

Product details

Additional specifications: Adopt the new Michelson self-compensation optical system, which can be dynamically corrected, spectral data real-time collection, light source: imported long-life high-intensity air-cooled ceramic infrared light source, detector: imported low noise DLATGS; Laser VCSEL Laser, beam diameter (mm) 10, beam diameter (mm) 30 at the sample; Including electronic moisture-proof box and temperature and humidity meter, instrument moisture-proof drying box with heating and dehumidification function. Effectively prolong the service life of the Fourier infrared host. The body with LED display screen, real-time display of temperature and humidity, effectively monitor the use of the environment, protect the equipment; Under the OS Windows11 system, weight (kg) 18, ambient temperature (℃) 15-28, relative humidity (%) <50% (no condensation). Data transmission USB2.0, operating voltage AC220V DC12V 40W. Overall dimensions (mm) 460 * 4000 * 210, sample chamber size (mm) 200 * 175 * 153; software: FTIR 8800 The window software is provided along with the whole system. This software can meet the requirements of all standard analysis, including spectral data processing, instrument control, multiple map simultaneous preview. Filtering, baseline correction, interactive editing, and data manipulation are also provided on analytical models of interferograms or spectra. At the same time, there are spectral deduction, hybrid deduction, filter derivative, spectrum preview and other functions. Data input and output can be in either ASCII or JCAMP format. Other commercial programs including Thermo / Galactic GRAMS can also be used, such as a gallery search. Interspec The software program is written in a 32-bit protection mode. We have designed specialized software for applications with different functions, which is easy to operate and free to offer. By adding other business programs, such as search, component identification, Kramers Kronig transformation, chemical statistics, etc., extend the program functions to meet individual requirements; Fourier transform infrared spectrometer host, AC power adapter and cable, USB data line, standard checksheet, color changing silicone (desiccant), quick operation guide, application software, supporting tools, and computer and printer users; Optional attachment: ATR accessories, mirror reflection accessories, reflective diffuse reflection accessories, FW series powder press, HF series press die, HF series liquid test accessories, HF series gas test accessories, HW series infrared drying box, cuvette and cuvette tray, etc.