Delivery location+675 72 111 999Consulting & AdvisoryFor Institutions & Bulk Orders
Fully automatic headspace sampling device LN-AHS-50 — view 1

Fully automatic headspace sampling device LN-AHS-50

SKU: MW-LN-AHS-50

innovation point 1、The rotary valve switching multi-dimensional gas path injection system has completely overcome the drawbacks of domestic six-way valves and ten-way valves, such as short service life and inability to withstand high temperatures 2. The gas path flow design is very simple, reliable and conducive to leakage prevention, greatly improving work efficiency 3. Both the gas path through which the sample passes and the sample valve have adopted inertization treatment technology 4.

Price on request

Sign in and submit a request to see pricing for this product.

Specifications

ModelLN-AHS-50
Country of Originchina
Technical indicators / WeightApproximately 40Kg
Technical indicators / Heating stations8
Technical indicators / Instrument power< 1000VA
Technical indicators / Instrument dimensionsHeight × width × length :580mm×564mm×666mm
Technical indicators / Headspace vial stations50
Technical indicators / Analytical repeatabilityRSD<1% (related to GC performance and operational techniques)
Technical indicators / Cylinder drive air pressure< 0.4MPa (adjustable)
Technical indicators / Headspace vial specificationStandard 20ml
Technical indicators / Foreign affairs time control range0.1 to 99 minutes, timing error: <0.1%
Technical indicators / Sample temperature adjustment rangeroom temperature to 380℃, accuracy ±0.5℃, increment 1℃, set freely
Technical indicators / Pipeline temperature adjustment rangeroom temperature to 260℃, accuracy ±0.5℃, increment 1℃, set freely
Technical indicators / Controllable number of foreign affairs15
Technical indicators / Interlocking signal output switch time<2 seconds
Technical indicators / The temperature adjustment range of the six-way valveroom temperature to 260℃, with an accuracy of ±1℃ and an increment of 1℃, which can be set freely
Technical indicators / Pressure resistance of the airway and related components>0.4MPa

Product details

innovation point 1、The rotary valve switching multi-dimensional gas path injection system has completely overcome the drawbacks of domestic six-way valves and ten-way valves, such as short service life and inability to withstand high temperatures 2. The gas path flow design is very simple, reliable and conducive to leakage prevention, greatly improving work efficiency 3. Both the gas path through which the sample passes and the sample valve have adopted inertization treatment technology 4. The gas path is optional (EPC electronic pressure control), and the digital display is more intuitive. It can achieve automatic gas path system leak detection and ancient fault alarm 5. By adjusting the injection volume through the injection time, it can analyze samples of different concentrations and various standards, and can store 10 methods 6. Full-color screen display, friendly interface, touch operation, allowing for quick and easy mastery. It tracks and displays the entire operation process, set parameter values, and real-time values, etc 7. Eight preheating stations are set up, which can achieve cyclic heating and improve the analysis efficiency