Delivery location+675 72 111 999Consulting & AdvisoryFor Institutions & Bulk Orders
GGZ-AD-I Children CPAP System Medical Ventilator — view 1

GGZ-AD-I Children CPAP System Medical Ventilator

SKU: MW-GGZ-AD-I
Price on request

Sign in and submit a request to see pricing for this product.

Specifications

CPAP3-10cmH2O
FIO221-100% (±3%)
FiO221%-100%(±3%)
Flow2-18LPM
AD-IAAD-II
AlarmGas supply pressure difference > 0.1MPa
ModelAD-I
Noise≤52 dB(A)
1-10LPM2-18LPM
Packingcarton packaging
TrolleyYes
Built-inPN-3000(Optional)
CPAP (2)3-10cm H2O
Flow (2)0-18 LPM
OptionalYes
3-10cmH2O0-10cmH2O
Noise (2)≤52dB(A)
Gas sourceAir/Oxygen@0.3-0.4MPa
≤52 dB(A)≤52 dB(A)
Power SourceAC 220V, 50-60Hz (Optional: AC 110V, 50-60Hz)
Power sourceAC220V/110V,50-60Hz
21%-100%(±3%)21%-100%(±3%)
Air CompressorPN-4000 (Optional)
Air compressorPN-4000(Optional)
CPAP GeneratorYes
Package Weight44.7KG
Oxygen AnalyzerOptional
Parts / Max flow180L/min
Package Dimensions74*46*85cm
AC220V/110V,50-60HzAC220V/110V,50-60Hz
Air/Oxygen@0.3-0.4MPaAir/Oxygen@0.3-0.4MPa
Common parameter / Power220V AC 50Hz
Parts / Capacity of Chamber280ml(F-Adult); 230ml(FA-Infant)
Parts / Working temperature30℃~37℃
Parts / Max working pressure2kPa
Performance parameter / FIO221%~100>#br###Flow: 0~18LPM
Performance parameter / Alarmthe differential pressure> 0.1MPa, sound alarm
Common parameter / CertificationISO 13485 CE
Performance parameter / CPAP pressure0.3~1.0kPa(3~10cmH2O)
Parts / Max temperature of heating plate85℃
Common parameter / Pressure of oxygen and air0.3MPa~0.4MPa
Matching solution of Medical Air Compressor / Flow>25L/ruin
Matching solution of Medical Air Compressor / Noise<52dB(A)
Performance parameter / Water capacity of Generator500ml or more
Matching solution of Medical Air Compressor / Output pressure0.20MPa~0.30MPa
Matching solution of Medical Air Compressor / Max exhausting pressure0.7MPa

Product details

Additional specifications: Application: Bubble CPAP is a sort of special medical equipment for supporting of babies’ breath which devised and manufactured based on the wide application of closed continuous NCPAP in department of pediatrics. It uses on the course of ventilation treatment of Nasal-CPAP for premature, neonate, infant to children below 14 year old. The mode of CPAP can reduce babies’ WOB effectively, while keeping the autonomous respiration well; Superiority: Supply a safe and controllable FIO2; Superiority: Keep the FRC effectively; Superiority: Reduce infant’s WOB; Superiority: Reduce the need of invasive mechanical ventilation; Superiority: Supply better warm and humid gas; Superiority: Reduce the occurrence rate of the CLD; Superiority: Improve the physical sighs, such as height, weight; Parts: Matching with Medical Electric Respiratory humidifier(PN-2000F/FA); CPAP Generator: It is easy to set the oscillating gas pressure from 3cmH2O to 10cmH2O through adjusting the CPAP pressure bar; CPAP Generator: The automatic regulating mechanism of water-level ensure the constant CPAP pressure; CPAP Generator: The dismountable chamber is very convenient.