ICU Ventilator MDW-CWT80
SKU: MW-ICU-Ventilator-MDW-CWT80
Price on request
Sign in and submit a request to see pricing for this product.
Specifications
| Model | ICU Ventilator MDW-CWT80 |
| Weight | Approximately 13kg ( Main unit) |
| O2 Remdy / Flow | 4-60L/min |
| Dimensions(L*W*H) | 40*42*36cm |
| Display / Brightness | Adjustable |
| Power Battery / Input | 2.5A Max |
| Display / Display size | 12.1 inch TFT touch screen |
| Gas Supply / Gas Supply | Medical-grade Oxygen |
| Ventilation modes / PCV | Pressure Control Ventilation |
| Ventilation modes / PSV | Pressure Support Ventilation |
| Ventilation modes / VCV | Volume Control Ventilation |
| Ventilation modes / AC-P | Assist Control-Pressure Ventilation |
| Ventilation modes / AC-V | Assist Control-Volume Ventilation |
| Ventilation modes / APRV | Airway Pressure Release Ventilation |
| Ventilation modes / CPAP | Continuous Positive Airway Pressure |
| Ventilation modes / BIPAP | Bilevel Positive Airway Pressure |
| Ventilation modes / PA-VC | Pressure Auto-Volume Control |
| Controlled Parameters / MV | 250-1500ml/min |
| Controlled Parameters / VT | 2-2000ml |
| Ventilation modes / SIMV-P | Pressure Synchronized Intermittent Mandatory Ventilation |
| Ventilation modes / SIMV-V | Synchronized Intermittent Mandatory Ventilation-Volume |
| Controlled Parameters / Fio2 | 21-100Vol% |
| Controlled Parameters / PEEP | 0-40cmH2O |
| Controlled Parameters / Sigh | On/Off, 1/5 times every 100 breath cycle |
| Display / Display Resolution | 1280*800pixels |
| Gas Supply / In put pressure | 280-600kpa |
| Power Battery / Battery type | Build-in Lithium-ion Battery, 12V |
| Trend & Event Log / Event Log | 3000 logs |
| O2 Remdy / Oxygen concentration | 21%-100% |
| Power Battery / Input Frequency | 50/60Hz |
| Trend & Event Log / Trend Length | 72 hrs for monitoring parameters |
| Loops / Waveforms and loops display | Could simultaneous display 3 waveforms and 3 loops. |
| Controlled Parameters / Flow-trigger | 0.5-30L/min |
| Controlled Parameters / Min Tinsp/Texp | 150-1000ms |
| Controlled Parameters / Pressure-trigger | -20-20cmH2o |
| Controlled Parameters / Respiratory rate | 4-200bpm |
| Ventilation Specification / Patient Type | Adult, Pediatric, Neonatal |
| Trend & Event Log / Communication Interface | HDMI, Ethernet, USB, CO2 Module Connector(Optional) |
| Ventilation Specification / Ventilation Type | IV & NIV |
| ENVIRONMENTAL OPERATING CONDITIONS / Quantity | Range |
| Controlled Parameters / Max Inspiration pressure | 90cmH2O |
| ENVIRONMENTAL OPERATING CONDITIONS / Noise generation | <45 dB |
| Power Battery / External AC Power Supply Input Voltage | 100-240V |
| ENVIRONMENTAL OPERATING CONDITIONS / Ambient Air Pressure | 500-1100 mbar |
| ENVIRONMENTAL OPERATING CONDITIONS / Relative air humidity | 5-95% R.H. |
| ENVIRONMENTAL OPERATING CONDITIONS / Temperature (around module) | -20-+60 degrees C |
| ENVIRONMENTAL OPERATING CONDITIONS / Operating temperature (outside) gas inlet | -20-+50 degrees C |