Delivery location+675 72 111 999Consulting & AdvisoryFor Institutions & Bulk Orders
ICU Ventilator MDW-CWT80 — view 1

ICU Ventilator MDW-CWT80

SKU: MW-ICU-Ventilator-MDW-CWT80
Price on request

Sign in and submit a request to see pricing for this product.

Specifications

ModelICU Ventilator MDW-CWT80
WeightApproximately 13kg ( Main unit)
O2 Remdy / Flow4-60L/min
Dimensions(L*W*H)40*42*36cm
Display / BrightnessAdjustable
Power Battery / Input2.5A Max
Display / Display size12.1 inch TFT touch screen
Gas Supply / Gas SupplyMedical-grade Oxygen
Ventilation modes / PCVPressure Control Ventilation
Ventilation modes / PSVPressure Support Ventilation
Ventilation modes / VCVVolume Control Ventilation
Ventilation modes / AC-PAssist Control-Pressure Ventilation
Ventilation modes / AC-VAssist Control-Volume Ventilation
Ventilation modes / APRVAirway Pressure Release Ventilation
Ventilation modes / CPAPContinuous Positive Airway Pressure
Ventilation modes / BIPAPBilevel Positive Airway Pressure
Ventilation modes / PA-VCPressure Auto-Volume Control
Controlled Parameters / MV250-1500ml/min
Controlled Parameters / VT2-2000ml
Ventilation modes / SIMV-PPressure Synchronized Intermittent Mandatory Ventilation
Ventilation modes / SIMV-VSynchronized Intermittent Mandatory Ventilation-Volume
Controlled Parameters / Fio221-100Vol%
Controlled Parameters / PEEP0-40cmH2O
Controlled Parameters / SighOn/Off, 1/5 times every 100 breath cycle
Display / Display Resolution1280*800pixels
Gas Supply / In put pressure280-600kpa
Power Battery / Battery typeBuild-in Lithium-ion Battery, 12V
Trend & Event Log / Event Log3000 logs
O2 Remdy / Oxygen concentration21%-100%
Power Battery / Input Frequency50/60Hz
Trend & Event Log / Trend Length72 hrs for monitoring parameters
Loops / Waveforms and loops displayCould simultaneous display 3 waveforms and 3 loops.
Controlled Parameters / Flow-trigger0.5-30L/min
Controlled Parameters / Min Tinsp/Texp150-1000ms
Controlled Parameters / Pressure-trigger-20-20cmH2o
Controlled Parameters / Respiratory rate4-200bpm
Ventilation Specification / Patient TypeAdult, Pediatric, Neonatal
Trend & Event Log / Communication InterfaceHDMI, Ethernet, USB, CO2 Module Connector(Optional)
Ventilation Specification / Ventilation TypeIV & NIV
ENVIRONMENTAL OPERATING CONDITIONS / QuantityRange
Controlled Parameters / Max Inspiration pressure90cmH2O
ENVIRONMENTAL OPERATING CONDITIONS / Noise generation<45 dB
Power Battery / External AC Power Supply Input Voltage100-240V
ENVIRONMENTAL OPERATING CONDITIONS / Ambient Air Pressure500-1100 mbar
ENVIRONMENTAL OPERATING CONDITIONS / Relative air humidity5-95% R.H.
ENVIRONMENTAL OPERATING CONDITIONS / Temperature (around module)-20-+60 degrees C
ENVIRONMENTAL OPERATING CONDITIONS / Operating temperature (outside) gas inlet-20-+50 degrees C

Product details

Additional specifications: The CWH-T80 is an advanced turbine ventilator for provide acute respiratory support for adult, pediatric and neonatal use. Excellent ventilation performance and comprehensive monitoring capabilities adapt to various clinical requirements; NEW generation of ventilator: Molding production, tight structure; NEW generation of ventilator: Turbine driven machine; NEW generation of ventilator: 12.1 inch touch screen; NEW generation of ventilator: New interface design with user friendly layout and color assortment; NEW generation of ventilator: Intelligence operating system; NEW generation of ventilator: Can display 3 types of waveform in same interface; NEW generation of ventilator: 3 level of audio and visual alarm indication, adjustable sound volume; Ventilation performance: Integrated turbine design can continuous delivery high low more than 220L/min with rapid response of compensation; Ventilation performance: Comprehensive ventilation modes for volume and pressure based, with selection of pressure support, spontaneous breath and non-invasive ventilation. Ventilator is applicable for wide range of patients and clinical situations; Ventilation performance: Quick response for patient’s trigger which improved the synchrony between patient- ventilator; Ventilation performance: Graphic capabilities for trends and event record, long time monitoring for all types of ventilation parameters; Ventilation performance: Provide respiratory support from neonatal to adult; Approximately 26kg ( with Trolley); Ventilation modes: APNEA; Ventilation modes: Assistant therapy; Ventilation modes: Nebulization; Ventilation modes: O2 Remedy; Ventilation modes: Real Time Graphics; Waveforms: Pressure-time Waveform; Waveforms: Flow-time Waveform (Waveforms with freeze function); Loops: Pressure-volume Loop; Loops: Flow-time Loop; Loops: Pressure-flow Loop( Loops with freeze, Zoom in out, comparison function); Controlled Parameters: Monitoring Parameters; Controlled Parameters: VTe mand, VTe spon, VTi mand, VTi spon Mvemand, Mve spon, Mvimand, Mvi spon, MVe total, RR mand, RR spon., Tinsp Texp, Ppeak, Pplat, PEEP, Pmean, FiO2, Vleak, Flowpeak_insp, Flowpeak_exp, Pmin, RSBI, P0.1, C, R, RCinsp, RCexp, WOB; Trend & Event Log: Communication Interface; 625*745*1540mm 80KG.