ICU ventilator standard configuration MDW-3010S
SKU: MW-MDW-3010S
Key features: 12.1 inch touch screen with desirable color schemes; The simplest interface boots a precise control and convenient operation; Applied for adult,pediatric and infant; Multi-mode ventilation function (VCV,SIMV,SIMV/PSV,PSV,PCV,APRV,APNEA,CPAP,BIPAP,Manual,SIGH).
Price on request
Sign in and submit a request to see pricing for this product.
Specifications
| Loops | P-V, F-V, F-P |
| Model | MDW-3010S |
| Screen | 12.1 inch touch screen |
| Weight | 65kg |
| Casters | Front wheels with lock |
| Display | Colour LCD |
| Packing | woodencase |
| Main unit | 560*510*650mm, NW: 11kg, GW: 21kg. |
| Materials | ABS |
| Dimensions | 45*55*140cm |
| PEEP / Type | Integrated, Electronic control |
| PEEP / Range | OFF, 3-40 cmH2O |
| Display graphics | Waveforms of P-T, F-T, V-T |
| Country of Origin | CHINA |
| Package Dimensions | 560*510*650mm |
| Air compressor / NW | 65kg, GW: 83kg |
| Battery Power / Run-time | Typical 180 mins+ |
| Ventilator Parameter / SIGH | Off, 1-5/100 |
| Battery Power / Battery Type | Lead-acid 12V,4Ah |
| Typical function / O2 remedy | Up to 60L/min |
| Pre-setting Functions / Language | English |
| Pre-setting Functions / Self-test | AUTOMATIC |
| Environmental Conditions / Humidity | ≤80% |
| Parameter monitoring / Visual/Audio | No tidal volume, MV, Paw, FiO2 limitation O2, Air failure, AC power failure, backup low |
| Pipeline Supply / Gas configuration | O2,Air |
| Air Compressor Specifications / Noise | ≤50dB |
| Air Compressor Specifications / Power | AC 220V+/-10%, 50Hz+/-2% |
| Ventilator Parameter / Ftrigger Range | 0.3-30L |
| Ventilator Parameter / Pressure range | 5-80 cmH2O |
| Ventilator Parameter / Ptrigger Range | -20-20cmH2O(based on PEEP) |
| Pipeline Supply / Pipeline input range | 280-600Kpa |
| Environmental Conditions / Storage Temp | -10℃-+40℃ |
| Ventilator Parameter / Inspiration time | 0.2-12s |
| Environmental Conditions / Operating Temp | 5℃-40℃ |
| Ventilator Parameter / Tidal Volume range | 20-2000ml(can be optional 10ml) |
| Ventilator Parameter / Inspiration plateau | Off, 1-50% |
| Ventilator Parameter / Oxygen concentration | 21%-100% |
| Typical function / Auxiliary Suction function | Optional |
| Ventilator Parameter / Rispriation Rate Range | 1-100bpm(1-40bpm under SIMV) |
| Environmental Conditions / Atmosphere pressure | 960hPa-1040hPa |
| Air Compressor Specifications / Output pressure | 0.4+/-0.1MPa |
| Ventilator Specifications / Modes of Ventilation | VCV,APNEA,SIMV,SIMV/PSV,MANUAL,CPAP,PSV,PCV,BIPAP,SIGH,APRV,NIV |
| Ventilator Parameter / Pressure control/Pressure support | 0-80 cmH2O |