1 / 2
Inductively-coupled plasma-based emission spectrometer
SKU: MW-ICP-7000-type
Price on request
Sign in and submit a request to see pricing for this product.
Specifications
| Model | ICP-7000-type |
| Country of Origin | jiangsu |
| within 20s / Instrument size | 1350x800x650mm (LxWxH) |
| within 20s / Instrument quality | 145kg of the host unit |
| within 20s / Element detection limit | most elements 1 ppb-10 ppb (μg/L) |
| within 20s / Instrument power supply | AC220V / 20A |
| 1.2.RF source parameters / Output power | 500W-1650W |
| 1.4.Technical index of spectroitter / Grating | Roland circular grating 3600l / mm |
| 1.2.RF source parameters / Frequency stability | <0.05% |
| 1.4.Technical index of spectroitter / Fay light | equivalent background concentration of 10000 ppm Ca at As189.042nm <2ppm |
| 1.4.Technical index of spectroitter / Stability | Relative standard deviation RSD <1%@2 hours |
| 1.4.Technical index of spectroitter / Resolution | <7pm-200nm |
| 1.4.Technical index of spectroitter / Test speed | a single CMOS readout time is only 2ms, and all elements can be measured |
| 1.2.RF source parameters / Output power stability | <0.05% |
| 1.2.RF source parameters / Power supply frequency | 27.12MHz |
| 1.4.Technical index of spectroitter / Focus length | 400mm |
| 1.4.Technical index of spectroitter / Length range | 165nm-950nm |
| 1.4.Technical index of spectroitter / Light chamber | constant temperature of 34 soil 0.1℃1.5.Instrument technical indicators |
| 1.4.Technical index of spectroitter / Repeatability | (i. e. short-term stability) relative standard deviation RSD <0.5% |
| 1.3.Technical index of the injection device / Peristtic pump | four channels twelve rollers, the speed can be set according to the demand |
| 1.1. Technical indicators of the detection device / Detector type | the original CMOS detector in Japan |
| 1.3.Technical index of the injection device / Output working coil | silver-plated high-frequency coil with an inner diameter of 25mm and 3 |
| 1.4.Technical index of spectroitter / Double measurement direction | axial / radial observation |
| 1.3.Technical index of the injection device / Total argon consumption | the total argon consumption is less than 14 L/min |
| 1.1. Technical indicators of the detection device / Quantum efficiency | without any coating, the quantization efficiency can reach more than |
| 1.3.Technical index of the injection device / High efficiency inlet atomizer | concentric atomizer, outer diameter 6mm; multiple models |
| 1.3.Technical index of the injection device / Three concentric quartz torch tube | outer diameter of 20mm; various models are available in |