liquid chromatograph LN-LC-1000E — view 1

liquid chromatograph LN-LC-1000E

SKU: MW-LN-LC-1000E

Ultra-low noise and outstanding quality provide you with reliable analysis results. The powerful reverse control software, data processing and reporting functions can flexibly meet any requirements of the analysis work. It offers an extremely high cost performance. The LC-1000E high-performance liquid chromatograph features a stable liquid flow and high-quality imported optical components. It is a reliable and highly sensitive ultraviolet-visible variable dual-wavelength analytical .

Price on request

Sign in and submit a request to see pricing for this product.

Specifications

ModelLN-LC-1000E
Country of OriginCHINA
Multi-mode wavelength scanning3 scanning modes, with programmable wavelengths;
New automatic wavelength correction. Wavelength accuracy0.1nm, wavelength repeatability: 0.1nm. Noise: =0.25×10-5 AU. Drift: =0.5×10-4 AU. Flow cell volume: 10 μ l;

Product details

Ultra-low noise and outstanding quality provide you with reliable analysis results. The powerful reverse control software, data processing and reporting functions can flexibly meet any requirements of the analysis work. It offers an extremely high cost performance. The LC-1000E high-performance liquid chromatograph features a stable liquid flow and high-quality imported optical components. It is a reliable and highly sensitive ultraviolet-visible variable dual-wavelength analytical . The processing and customization of the core components are all completed in the United States. 1. The Electrical Dump Control technology and electronic CAM technology are adopted to control the flow pulsation, effectively ensuring the accuracy and repeatability of the flow, and guaranteeing a relatively low baseline noise; The volume of liquid discharged in a single stroke is 30 μ l. Flow range: 0.0001-9.999 ml/min, increment: 0.0001ml/min; The maximum pressure resistance is 62Mpa and the flow accuracy is ≤0.02%. Detection system: Both deuterium lamps and tungsten lamps are installed simultaneously, and it can automatically switch to full wavelength scanning. Dual-wavelength detection, wavelength-time programming; Wavelength range: 190nm-900nm, wavelength accuracy 0.1nm, spectral bandwidth 8nm. Gradient mixing precision: 0.1% or 1ul/min, gradient mixing repeatability: RSD = 0.1%, injection repeatability: RSD = 0.1%. Sensitivity: ≤2×10-10g/ml methanol solution of naphthalene. Reverse control workstation: The workstation can set and control all instrument parameters and automatic samplers, fully automatically track all critical parameters of liquid chromatography and prompt users when interference and errors occur, provide online guidance for the system to automatically detect, and facilitate maintenance. It has the functions of three-level management and audit trail, and fully complies with the requirements of CFDA GxP and FDA 21CFR-Part11. When conducting dual-wavelength determination, a proportional chromatogram is output, and the component content is obtained through the built-in algorithm. 2. Long service life of the sealing ring, multi-point flow correction curve, ensuring flow accuracy throughout the full flow range; 3. The plunger suspension transmission technology design ensures the service life of the high-pressure sealing ring. It adopts a double-plunger parallel pump structure, with the two pump heads alternating for liquid infusion. Under the same infusion volume, the service life of the piston rod and the sealing ring is twice as long as that of the series pump. 4. The automatic plunger cleaning function can clean the back of the plunger and the plunger sealing ring, preventing the service life of the sealing ring from being shortened due to the crystallization of high-salt concentration buffer solution. 5.GLP function pressure curve, flow curve, and record the usage times of the plunger rod sealing ring. Pressure pulsation: = 0.1%, maximum pressure resistance: = 45 Mpa(ASI pump head) 6. The dual-path optical system can achieve dual-wavelength detection. 7. The monochromator adopts high-precision control to enhance wavelength accuracy. 10. All parameters are displayed on the LCD screen, which can be set either by the instrument itself or through the reverse control workstation. 99 user programs are available, enabling programming for flow, gradient and wavelength. 11. The open-source computer reverse control communication protocol for third-party software interfaces facilitates control by third-party software.