Delivery location+675 72 111 999Consulting & AdvisoryFor Institutions & Bulk Orders
Portable Emergency Ventilator MDW-CW2010 — view 1

Portable Emergency Ventilator MDW-CW2010

SKU: MW-MDW-CW2010

1. Certificated by CE and ISO 9001/13485. 2. Pneumatic driven, Electronic control. 3. Advanced monitoring and alarm systems for patient-related parameters. 4. Intelligence operating system. Easy to carry. Anti-shock, anti-interference and waterproof. Can be used in emergency department, transport, outdoor aid, per-hospital aid and beside the bed.

Price on request

Sign in and submit a request to see pricing for this product.

Specifications

GW16kg In carton
ModelMDW-CW2010
Gas / O2, AirO2 or air
Gas / Pipeline input Range280kpa-600kpa
Ventilation Specification / IE Ratio:4:1-1:8
Internal Rechargeable / Car ChargerDC 12V
Internal Rechargeable / Screen Size5.7 inch
Ventilation Specification / Sigh times1-5(Every 100 times)
Ventilation Specification / Tidal Volume50-2000ml
Ventilation Specification / Breathing Rate4-100/min
Internal Rechargeable / Sealed Lead Acid,12V>4 Hours
Ventilation Specification / Pressure Trigger-2kpa-0kpa
Ventilation Specification / Inspiratory Duration0.2-6s
Ventilation Specification / Oxygen concentration45%-100%

Product details

1. Certificated by CE and ISO 9001/13485. 2. Pneumatic driven, Electronic control. 3. Advanced monitoring and alarm systems for patient-related parameters. 4. Intelligence operating system. Easy to carry. Anti-shock, anti-interference and waterproof. Can be used in emergency department, transport, outdoor aid, per-hospital aid and beside the bed. Additional specifications: Power Input; 220V(+/-10%),50Hz(+/-2%) or 110V/60Hz; Battery Back-up; Ventilation Specification: Ventilation Mode; Ventilation Specification: IPPV, SPONT/CPAP, A/C, SIGH SIMV, MANUAL; Ventilation Specification: Inspiratory trigger sensitivity; Ventilation Specification: Monitoring; Ventilation Specification: Tidal volume, Ventilation volume, Breathing rate, peak, Oxygen concentration(Optional); Ventilation Specification: Waveform Display; Ventilation Specification: Pressure-Time; Ventilation Specification: Alarms; Ventilation Specification: Apnea; Ventilation Specification: Vt too high(low); Ventilation Specification: Airway Pressure too high; Ventilation Specification: O2 or Air supply failed; Ventilation Specification: AC power failure; Ventilation Specification: Battery under voltage; Ventilation Specification: No tidal Volume; 580*480*350mm.